700- LT1-Man Rev 8 09 Feb 2021
Page 43/60
If two SDI-12 sensors are connected to the LT1, there will be two responses returned, one for each
address. In order to determine the sensor which corresponds to each address, review each sensor’s
configuration page or remove one sensor and re-send the address query command.
If there is an address conflict (both sensors have the same address), one sensor will have to be
removed and the change address command sent to the connected sensor.
6.4
CONFIGURING A COUNTER SENSOR (TIPPING BUCKET)
Select the Counter line from the Station Dashboard and the Load from Template. Load the
appropriate template and fill in the fields.
6.4.1
LT1-CELL: TIPS BEFORE TRANSMISSION
The
Tips before Transmission
option appears on LT1-CELL units. When enabled, the LT1 will
transmit in accordance with the scheduled transmission and when the input number of tips has
been reached.
Select the enable box and
input the desired number of
tips