Forced infeed attempts
If the light barrier still does not come down after the set
number of forced infeeds, an error message will be issued.
Screw at address
Address at which the screw has been connected.
Minimum current monitoring active
Indicates whether the minimum current is being monitored
during operation.
Operating hours of screw on LB
Operating hours of screw on light barrier.
4.8.2 Feed system - Screw 2 on LB
System menu
Feed system
Screw 2 on LB
Screw active
▪ NO: Screw 2 on feed system module is not used.
▪ YES: Screw 2 on feed system module is used.
– “Screw 2” output
– “Gravity shaft cover 2” input
– “Light barrier 2” connection
Nominal current for screw 2
Nominal current for the motor of “screw 2” motor according
to the identification plate on the motor.
During troubleshooting of feed screw, it turns backwards
for
Duration, how long should the feed screw turn backwards
during troubleshooting.
During troubleshooting of feed screw, it turns forwards for
Duration, how long should the feed screw turn forwards
during troubleshooting.
Switch-on delay feed screw light barrier
Feed screw startup delay. If no fuel is detected in the
gravity shaft over the set time, the feed screw will start.
Switch-off delay feed screw light barrier
Feed screw switch-off delay. If no fuel is detected in the
gravity shaft during the set time, the feed screw will stop.
Maximum idle time of screw
Time delay until an error in the material recognition is
tripped.
Forced infeed after
The forced infeed happens after the runtime of the follow-
up screws. The screw is activated after a certain period of
time, even though the light barrier can currently still see
material.
Forced infeed maximum runtime
Maximum duration of forced infeed. The screw then
pauses.
Forced infeed attempts
If the light barrier still does not come down after the set
number of forced infeeds, an error message will be issued.
Minimum current monitoring active
Indicates whether the minimum current is being monitored
during operation.
Operating hours of screw on LB
Operating hours of screw on light barrier.
Screw at address
Address at which the screw has been connected.
4
Parameters overview
Feed system
72