4.16.2 Touchscreen - Display operating rights
System menu
Touchscreen
Display
operating rights
In this menu the operating rights for the individual room
consoles are allocated. If access from a room console to a
heating system component is permitted, the corresponding
parameter must be set to “YES”. The number of menus as
well as the parameter entries depend on the system
configuration!
NOTICE! The operating rights of the room consoles should
be allocated from the boiler console, as unrestricted access
is only possible here.
“Touch display with address 1 – 7” and “Button display with address 1 – 7”
Heating circuit system:
Allow access to heating circuit 01 ... 18?
Specifies whether heating circuit 01 … 18 can be
accessed from touchscreen 1 … 7.
DHW tank system:
Allow access to DHW tank 01 ... 08?
Specifies whether DHW tank 01 … 08 can be accessed
from touchscreen 1 … 7.
Storage tank system:
Allow access to storage tank 01 ... 04?
Specifies whether storage tank 01 … 04 can be accessed
from touchscreen 1 … 7.
Solar panel system:
Allow access to solar system 01?
Specifies whether solar system 01 can be accessed from
touchscreen 1 … 7.
Heating system:
The parameters displayed depend on the configuration.
Boiler:
Switch boiler on/off via room console
If this function is activated, the respective room console is
enabled for switching the boiler on and off. In order to be
able to operate the boiler, remote switching on the boiler
display must also be activated.
Froling Connect
System menu
Touchscreen
Display
operating rights
Froling Connect
For connection via the froeling-connect.com online platform
using a touchscreen, the issue of a password is required.
NOTICE! The same password can be assigned for each
touch display!
Password for boiler display
Password for boiler display can be issued.
Password for touchscreen with address 1 ... 7
Password for the touchscreen with address 1 … 7 can be
issued.