PARAMETERS
Page 58
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
DEFAULT PARAMETERS EUR
Level 1
Level 2
Default
Possibilities
Information
1.05.2007
software version
Manager
1111
Preheat allowed
yes
yes - no
Preheat temp
210
50 - 250
Holding allowed
no
yes - no
Holding temp
85
50 - 250
Cook Correction
1
yes
yes - no
Eco function
2
yes
yes - no
Language
English
"English - Nederlands - Deutsch - Francais -Espanol - Russian"
Big Digits
yes
yes - no
Sound preheat
T1,
T1 - T2 - T3
Sound step
T2,
T1 - T2 - T3
Sound done
T3,
T1 - T2 - T3
Service
4878
Preheat allowed
yes
yes - no
Preheat temp
210
50 - 250
Holding allowed
no
yes - no
Holding temp
85
50 - 250
Cook corr. Option
yes
yes - no
Cook corr. factor
3
1 - 6
Ecocook option
yes
yes - no
Ecocook var
6
1 - 9
Language
English
"English - Nederlands - Deutsch - Francais -
Espanol - Russian"
Big Digits
yes
yes - no
Sound preheat
T1,
T1 - T2 - T3
Sound step
T2,
T1 - T2 - T3
Sound done
T3,
T1 - T2 - T3
Temp unit
°C
°C - °F
Boost allowed
no
yes - no
User pin in use
no
yes - no
Lights out
yes
yes - no
Key beep
no
yes - no
Temp offset
0
-50 - +50°C or -100-+100°F
Key sense
7
1 - 11
Temp grad
3
"0 - 19
0 = disable error 55"
Second Display
0
0-1-2-3
Thermistor
3
no
yes - no
TDR gas = NO
Hood Check
no
yes - no
1 Only visible when “Cook Corr. option” in Service Menu is set on “yes”
2 Only visible when “Ecocook option” in Service Menu is set on “yes”
3 May be put on yes in case serial number higher than
100067526.
NOT in case of TDR gas!