PARAMETERS
Page 57
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
To store parameters from the CPU board to the memory stick is done as follows:
1. Place the memory stick and go to the Service menu (pincode 4878) choose “USB” and
confirm with “OK”.
2. Go to “store” and confirm with “OK”.
3. Choose “parameters”and confirm with “OK”.
4. Now choose a file name and confirm with “OK”.
5. Go to “save file” and confirm with “OK”.
Now the parameters will be written on the memory stick.
Notes:
• When the message “files not found” is indicated on the display try to reset the machine
by pulling the plug out for 5 seconds.
• The name of a parameter file may not exist of more than 8 characters and can’t have a
space between the characters.
• Check if there is a folder on the memory stick with the name “parameters”.
• If it still doesn’t work try to load the software again.
• All parameter name files must have the extension .csv.
Parameters can only be read to, or stored from the CPU board by means of a memory stick.
The transfer is always done out of a folder called “PARAMS”. This folder has to be placed
direct on the memory stick and cannot be placed in another folder, otherwise it will not
work. The folder can contain several parameter files. The name of a file may exist of maxi-
mum 8 characters and can’t have a space between the characters, otherwise it will not be
read or stored.
When reading a new parameter file to the CPU board the old parameters will be deleted. So
it’s adviseable to store the old program first on your memory stick.
To read a parameter list from a memory stick to the CPU board is done as follows:
1. Place the memory stick and go to the service menu (pincode 4878), choose “USB” and
confirm with OK.
2. Go to “read” and confirm with “OK”.
3. Choose “parameters”and confirm with “OK”.
4. Go to “read stick” and confirm with “OK”.
5. Choose file name, with “other file”, and confirm with “OK”.
6. Now go to “read file” and confirm with “OK”.
Now the new parameters will be loaded inside the CPU board.