Model UR-2 <MENU mode / SYSTEM SETUP menu>
You can set the analog reference level.
By default, the reference level is set to the "-20
dB" which is 20dB below the digital full scale level.
You can set it to "-12 dB" if required.
The setting is stored to the internal flash ROM.
By using the [MENU] dial to highlight "REF. level"
in the SYSTEM SETUP menu and pressing the [EN-
TER] key, the current setting starts flashing and
you can now select the reference level (the de-
fault setting is "-20dB").
Use the [MENU] dial to select a desired reference
level between "-20dB" and "-12dB", and press the
[ENTER] key to confirm the setting.
<Memo>:
The reference level is shown in inverse
video on the level meter scale (see below).
When the reference level is set to "-12dB"
When the reference level is set to "-20dB" (default)
Setting the reference level
You can set the peak hold time of the level meters
between 0 and 9 seconds in one second steps. By
default, it is set to three seconds.
The setting is stored to the internal flash ROM.
By using the [MENU] dial to highlight "Peak hold
time" in the SYSTEM SETUP menu and pressing
the [ENTER] key, the current setting starts flash-
ing and you can now select the peak hold time
(the default setting is "3sec").
Use the [MENU] dial to select a desired time be-
tween 0 and 9 seconds and press the [ENTER]
key to confirm the setting.
Setting the peak hold time
To exit the [MENU] mode, press the [STOP] key
(or the [EXIT] key).