Model UR-2 <Controlling from an external device>
(2)
Press the [ENTER] key.
The current setting (CLOSE by default) starts
flashing and you can now select CLOSE or
OPEN.
Close
Open
In the following procedure, it is assumed that the
display shows the main menu screen of the REMOTE
SET menu, on which the "Remote Sel." menu item is
set to "All".
You can control the unit from an external con-
troller using the [PARALLEL REMOTE] connector.
For controlling the unit remotely, set the "Re-
mote Sel." menu item in the REMOTE SET menu
of the MENU mode to "All" or "Remote", as de-
scribed in the previous page.
The following table shows the pin assignment of
the [PARALLEL REMOTE] connector. Each com-
mand is executed by short-circuiting the associ-
ated pin (any of 3 through 12 and 15 through
24) with the GND pin.
Pin No.
Signal
IN/OUT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
STOP TALLY
REC TALLY
STOP
REC
FF (SKIP)
SHIFT
10key-0
10key-2
10key-4
10key-6
10key-8
FOOT SW
GND
PLAY TALLY
PLAY
REC RDY
REW (SKIP)
MIC IN
10key-1
10key-3
10key-5
10key-7
10key-9
VCC (+5V)
IN
IN
IN
IN
IN
IN
IN
IN
IN
OUT (OC)
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
OUT (OC)
OUT (OC)
+10key
IN
(1)
Use the [MENU] dial to highlight "Parallel Setup"
and press the [ENTER] key.
The display shows the "Foot SW, Mode"
setting screen.
<Memo>:
The [FOOT SW] jack shares pin #12
(FOOT SW) and pin #13 (GND) of the [PARALLEL
REMOTE] connector.
Using [PARALLEL REMOTE] connector
<Note>:
The [FOOT SW] jack has the reverse set-
ting of Close/Open (Close by default).
See the following section for details.
(3)
Use the [MENU] dial to select CLOSE or OPEN
and press the [ENTER] key to confirm the
selection.
(4)
Press the [STOP] key to exit the MENU mode.
1
13
14
25
The unit starts playback when the ex-
ternal switch is closed.
The unit starts playback when the ex-
ternal switch is open.
By connecting a footswitch or an external device
which provides the fader start/stop terminals to
the [FOOT SW] jack, you can control playback/
stop of the unit remotely.
For controlling the unit remotely, set the "Re-
mote Sel." menu item in the REMOTE SET menu
of the MENU mode to "All" or "Remote", as de-
scribed in the previous page. Also appropriately
set the "Foot SW. Mode" item of the "Parallel
Setup" menu item in the REMOTE SET menu if
required (see below).
Using [FOOT SW] jack
Setting "Foot SW. Mode"
Flashing
<Note>:
The supply current of VCC is 200 mA
max. Do not short-circuit the VCC port (pin #25).
OUT: Open collector output for transport status signal (max.
voltage: 5 V, max. current: 50 mA)
<Memo>:
The TALLY signals are used for trans-
port status indication. You can use them for turn-
ing on indicators, etc.