47
(Fig. 18)
13. Please refer to below figures. To open the metal cover, unscrew the power module cover as
positioned.
6.5 Wiring Diagram
Please refer to the wiring diagram located on the last page of this manual and on the backside of
the receiver cover plate.
6.6 System Testing
1.
Connect the power source to the receiver and test the operation of each function to
ensure it operates in the same manner as the pendant controller.
2.
Ensure the MAIN contact relay can be properly controlled by the remote control.
3.
Ensure the limit switches on the crane that limit all travels are working properly.
4.
Ensure the pendant controller is located in a safe location where it would not interfere
with remote operation.
7. OPERATING INSTRUCTION
7.1 Power “ON” the System
1.
Insert the transmitter power key into the key-switch slot located on the right side of the transmitter
belly box.
2.
Push the transmitter power key inward and then rotate it clockwise to “1” position.
“1”
→
“ON”
“0”
→
“OFF”
3.
To activate the system, first turn the EMS button clockwise so that the red button pops up
.
To
activate the function “When transmitter power is turned on, emergency stop button is compelled to
press & release check”: Press emergency stop button and release.
4.
Press the START pushbutton to activate MAIN relay and the transmitter starts to send signals.
5.
After 5 minutes of inactivity, that is 5 minutes after the last pushbutton is released, the green light