41
3) Page 2: joystick/VR function display
①
Signal strength, 5 sections in total. Full 5-section is for the strongest signal, empty
5-section is for the weakest signal.
②
Joystick or VR output
Line 1: J1:+10.0V J2:24.0mA
J1 is for joystick 1 or VR1 output; J2 is for joystick 2 or VR2 output
Line 2: J3:-10.0V J4:00.0mA
J3 is for joystick 3 or VR3 output; J4 is for joystick 4 or VR4 output
Line 3: J5:0 STEP J6:5 STEP
J5 is for joystick 5 or VR5 output; J6 is for joystick 6 or VR6 output
Line 4: J7:NO USE J8:NO USE
J7 is for joystick 7 or VR7 output; J8 is for joystick 8 or VR8 output
Remark: Joystick, VR proportional voltage or current output is displayed as “calculated value”, not “measured
value”(*) from output terminal. (0~+5V
、
0~±5V
、
0~+10V
、
0~±10V
、
4~20mA
、
0~20mA & 0~24mA. The
approximate difference between LCD display value and output value is ±0.2)
4) Page 3: Relay function display
①
Signal strength, 5 sections in total. Full 5-section is for the strongest signal and empty
5-section is for the weakest signal.
②
Relay output
Line 1:
P1: 01 02 03 -- -- -- -- 08
P1 is to relay module card I. P1: In sequence to relay K01 ~ K08.
“01” is K01 RELAY ON, “--" is K01 RELAY OFF, “ ”(empty) is K01 RELAY not in use.
: : :
: : :
“08” is K08 RELAY ON
,
“--" is K08 RELAY OFF, “ “(empty) is K08 RELAY not in use.
Line 2:
P2: 09 -- -- -- -- -- -- 16
P2 is to relay module card II. P2: In sequence to relay K09 ~ K016
“09” is K01 RELAY ON, “--" is K09 RELAY OFF, “ ”(empty) is K09 RELAY not in use.
: : :
: : :
“16” is K16 RELAY ON
,
“--" is K16 RELAY OFF, “ “(empty) is K16 RELAY not in use.
Line 3:
P3: 17 -- -- -- -- -- -- 24
P3 is to relay module card III. P3: In sequence to relay K17 ~ K24
“17” is K17 RELAY ON, “--" is K17 RELAY OFF, “ ”(empty) is K17 RELAY not in use.
: : :
: : :
“24” is K24 RELAY ON
,
“--" is K24 RELAY OFF, “ “(empty) is K24 RELAY not in use.