27
EID switch
“No function ”is
not selectable
“No
function ”is
not selectable
“No check
compelled” is
not selectable
* Change transmitter EID b0~b3
* Switch ON, EID bit=1; switch OFF, EID bit=0.
* Either mix mode selector switch or EID ENALE is selectable
* Receiver with AUTOSCAN function select EID bit match or bit or function
LID switch
“No function ”is
not selectable
“No
function ”is
not selectable
“No check
compelled” is
not selectable
* Change transmitter LID b0~b3
* Switch ON, LID bit=1; switch OFF, LID bit=0.
* Only 1 out of 2 LID ENALE function is selectable for mix mode selector
switch
Digital
joystick 2~5
speeds
activating
button
“No function ”is
not selectable
“No
function ”is
not selectable
“Pre-checking”
is selectable
* Select the pushbutton so that the pushbutton may control the digital joystick.
* When the pushbutton is not depressed, only 1-speed is activated even if the
joystick is operated to 2~5 speeds.
* Joystick 2~5 speeds only activated with relay output when the pushbutton is
depressed without releasing.
* Maximum 4pcs pushbuttons.
* Pushbutton or auto-return toggle switch is acceptable. No corresponding
relay output.
* If the digital joystick is not controlled by this pushbutton, then the 2~5 speeds
is not limited at 1 speed.
* EMS button: In case of an emergency, press down the red emergency stop button (EMS) will immediately
deactivates the transmitter and receiver MAIN relay. This is the rotary return type.
After the emergency stop button is elevated, please refer to “Transmitter startup condition” on Page 28 to
restart.
EN ISO 13849-1 type:
Press emergency stop button and switch off the transmitter power immediately,
then the transmitter will stop sending commands. After the receiver is not receiving any signal for 1
second, MAIN relay will be off.
Regular type:
Press emergency stop button and the transmitter will be sending emergency stop command.
As soon as the receiver receives stop command, the MAIN relay will be off. When the emergency stop
button is pressed for more than 1.5 seconds, the transmitter power will be switched off automatically.
* START button: Press to start the system and activate the receiver MAIN relay at the same time
* KEY: Power switch
4.3.2 Function Settings:
* ID: Range 00000~FFFF (hex), length 20bit. Total 1,048,576 sets of unique ID codes. Each Alpha 6000
system with unique manufacturing ID setting. This will ensure that only commands from the matching
control transmitter can be carried out without any interference from other radio systems.
Remark 1: ID with 4 lower digit b[3:0] is called LID
Remark 2: Transmitter with function ”mix mode selector switch-LID function” or “LID switch” will replace the original LID.
Remark 3: Receiver with function ”LID bit match” or ”LID bit ” from AUTOSCAN will replace the original LID.
* Channel: The channel in use assigned
Remark 1: transmitter with function “mix mode selector switch-channel in use function” or ”intelligent channel change” will
replace the original channel in use.
Remark 2: Receiver with channel assigned from AUTOSCAN will replace the original channel in use.
* Service number: Alpha 6000 manufacturing serial number, for after service purpose.
* Manufacturing date: manufacturing date
* Customer remark: 16 alphabets or numbers recordable