operation priority to the other one.
Setting request:
Transmitter 1 is set as channel 1 and transmitter 2 is set as channel 2. AUTOSCAN
enable is set as 2 stages. 1
st
stage is set as the channel for transmitter 1 and 2
nd
stage is set as the channel
for transmitter 2. Select one single speed pushbutton and set as ”assigned pushbutton enter AUTOSCAN
function”. Except for different channels, setting for transmitter 1 & 2 has to be completely identical.
Enable method:
When the original transmitter in operation, receiver MAIN relay is ON, joystick or
neutral VR back to neutral position and single side VR back to 0° position, press down the assigned
pushbutton, then the receiver enters AUTOSCAN status and searches for the other transmitter. The
other transmitter has to START and standby, but no assigned pushbutton is pressed. After receiver
successfully catches the other transmitter, the AUTOSCAN function will stop and the operation priority is
transferred.
* Receiver relay setting
◎
LV relay: Transmitter low voltage relay or AUTOSCAN channel lock instruction
Function
ON:
Transmitter low voltage, LV relay ON
ON 2sec & OFF 2sec repeatedly:
Transmitter low voltage, LV relay ON 2sec & OFF
2sec repeatedly
ON 1sec & OFF 1sec repeatedly:
Transmitter low voltage, LV relay ON 2sec & OFF
2sec repeatedly
Shutoff
Transmitter battery change or transmitter shutoff:
Transmitter shutoff or change
fully charged battery.
(Not suitable for receiver channel AUTOSCAN enable)
Transmitter battery change:
Transmitter should change the fully charged battery.
◎
STOP relay:
Emergency stop relay
RELAY ON:
Press emergency stop button when MAIN relay is ON. Or, receiver is
started but transmitter emergency stop button is pressed.
RELAY OFF:
To activate emergency relay, transmitter non-emergency code has to be
received and receiver startup request has also to be met,
that is, MAIN relay is activated.
◎
ID relay: Identical to MAIN relay ON/OFF.
◎
START relay: Press START button on transmitter, START relay ON; release START button then
START relay OFF
◎
ALARM relay MAIN relay ON
Not in use.
ON 1~3sec: When MAIN relay ON, ALARM relay ON 1~3sec
MAIN relay OFF Not in use.
ON 1~3sec: When MAIN RELAY OFF, ALARM relay ON
1~3sec
* RELAY K1~K32 output position exchange: Corresponding function for relay K1~K32 is exchangeable at will.
Case 1:
Each relay module is available with DC output relay up to 8pcs. (The change of AC output relay is