17
JOYSTICK
FUNCTION
REQUEST
DESCRIPTION
0~
±
10V
0~
±
5V
* Installation:
Interface card
for
voltage/current
proportional
output. Please
make sure the
JUMPER in
front of the
output PORT is
plugged in the
V mark
position.
* Only for:
Proportional
joystick and
neutral type VR
Double axes proportional joystick:
* Neutral position as 0°, output 0V.
* Joystick Upper/Left axis 0° ~ +40° for 0 ~ +10V / 0~+5V
proportional output. (127 steps resolution)
* Joystick Lower/Right axis 0° ~ -40° for 0 ~ -10V / 0~-5V
proportional output. (127 steps resolution)
Single axis proportional joystick:
* Neutral position as 0°, output 0V.
* Joystick Upper axis 0° ~ +35° for 0 ~ +10V / 0 ~ +5V
proportional output. (127 steps resolution)
* Joystick Lower axis 0° ~ -35° for 0 ~ -10V / 0 ~ -5V
proportional output. (127 steps resolution)
Neutral type VR:
* 0° as rotating central position. Output 0V.
* Clockwise 0° ~ +120° for 0~+10V / 0~+5V proportional output.
(127 steps resolution)
* Counterclockwise 0° ~ -120° for 0~-10V / 0~-5V proportional
output. (127 steps resolution)
0~+10V
0~+5V
* Installation:
Interface card
for
voltage/current
proportional
output. Please
make sure the
JUMPER in
front of the
output PORT is
plugged in the
V mark
position.
* Availability:
All are
available except
for the digital
joystick.
Double axes proportional joystick:
* Neutral position, output 0V. Upper and Lower axis relays are
OFF.
* Joystick Upper/Left axis 0° ~ +40° for 0~+10V / 0~+5V
proportional output. (127 steps resolution)
Upper axis relay is ON, Lower axis relay is OFF.
* Joystick Lower/Right axis 0° ~ -40° for 0~+10V / 0~+5V
proportional output. (127 steps resolution)
Upper axis relay is OFF, Lower axis relay is ON.
Single axis proportional joystick:
* Neutral position, output 0V. Upper and Lower axis relays are
OFF.
* Joystick Upper axis 0° ~ +35° for 0~+10V / 0~+5V proportional
output. (127 steps resolution)
Upper axis relay is ON, Lower axis relay is OFF.
*
Joystick Lower axis 0° ~ -35° for 0~+10V / 0~+5V proportional
output. (127 steps resolution)
Upper axis relay is OFF, Lower axis relay is ON.
Neutral type VR:
* 0° as rotating central position, output 0V. Upper and Lower
axis relays are OFF.
* Clockwise 0° ~ +120° for 0~+10V / 0~+5V proportional output.
(127 steps resolution)