31
ON; if NG, then error status “MAIN relay lock” appear.
◎
Receiver power ON: Proceed with dynamic check when receiver power is ON. If pass, then start
the system; if NG, then error status “MAIN relay lock” appear.
◎
START and receiver power ON: Dynamic check for both operation and power ON conditions.
Remark 1: When MAIN relay is on dynamic check status, MAIN1 relay close and MAIN2 relay open. After MAIN1
relay feedback normally, MAIN2 relay close and MAIN1 relay open, then check MAIN2 relay
feedback.
* Receiver channel auto-scan
◎
Not enable: Receiver receives channel regularly
◎
Enable and transmitter power ON enables intelligent channel change: “receiver auto-scan
channels” and “transmitter power ON intelligent channel change” activate at the same
time.
Transmitter power On intelligent frequency change:
1. When the software setting is started, there will have 8 channels available automatically. The 8
channels are used for receiver auto scanning and the transmitter can also select the best
communication channel from them.
2. It takes 1~3 seconds for every channel selection when transmitter is started. Time for receiver
channel auto scanning is 1~6 seconds. (pre-set as master / slave channel exchange scanning
mode)
3. Transmitter encoder version has to be V02.08 (incl.) or above and setting software has to be
V03.05 (incl.) or above.
◎
Enable
Channel stage selection:
2~16 stages are available. Each stage may assign receiving channel, LID & EID.
Delay time for entering auto-scan channel:
0~3 seconds are available. Before entering channel auto-scan, the search will stay for
0~3 seconds at the original channel (optional). If transmitter signal is received and
matches the frequency auto-scan lock condition, then the system enters operation status
again. If delay time over 0~3 seconds, the system will enter frequency auto-scan status
again.
Master/slave channel auto-scan exchange mode:
Master channel is the previous channel in use; the rest 1~16 channels are slave
channels.
Master/salve channel auto-scan exchange sequence: Master channel ->1
st
setting channel -> Master channel ->
2
nd
setting channel ……… Master channel -> Last setting channel
↑___________________________________________________________________|
Non-master/slave channel auto-scan exchange sequence:
1
st
setting channel
->
2
nd
setting channel
………
Last setting channel
↑______________________________________________|
◎
Auto-scan lock, LV relay ON for 3 seconds: Enable LV relay first to select. The function is the
same as ALARM relay.