10 - 4
91/92/96/99/105
Users Manual
MEASURE MENU
The Measure menu gives direct access to over 30
measurements; the best operating mode is automatically
selected.
SCOPE MODE
Continuous Auto Set
Hands-free signal probing. Continuously follows input
signals from 15 Hz to 50 MHz and automatically selects the
proper time base, input range, and trigger level.
Min Max Envelope
Records the waveform excursions with a grey scale
envelope on both inputs.
40 ns Glitch detect
Sweep speeds 1
µ
s per division or slower on INPUT A.
Grey-scale display
Analog-like Grey-scale display.
Waveform Average
Smoothing up to 256 waveforms. 10 samples in Roll mode.
Vertical
Frequency Response, -3 dB ..................... DC to >100 MHz
(Fluke 105)
DC to >50 MHz (Fluke 91, 92, 96, 99)
AC coupled ................<10 Hz direct, <1 Hz with 10:1 probe
Coupling .................................................... AC, DC, Ground
Rise Time ............................................. <3,5 ns (Fluke 105)
<7 ns (Fluke 91, 92, 96, 99)
Sensitivity ................................................1 mV to 100 V/div
to 1 kV/div with 10:1 probe
Current probe scaling ................. 1 mA/div to 100,000 A/div
Modes ............................... A, -A, B, -B, A+B, A-B, A=x B=y
A, -A (FLUKE 91)
Input Impedance................................... 1 M
Ω
//25 pF direct,
10 M
Ω
//15 pF with 10:1 probe
Vertical Resolution.................................... 8 bit (256 levels)
Accuracy
............................................................±
(2% +1 pixel),
add 3% for 1 and 2 mV/div
Horizontal
Modes......................................Recurrent, Single Shot, Roll
RANGES:
Recurrent ...................................5 ns to 1 s/div (Fluke 105)
10 ns to 1 s/div (Fluke 91, 92, 96, 99)
Dual input alternating
........5 ns (10 ns) to 20
µ
s/div
Dual input chopped
..........................50
µ
s to 1 s/div
91
91
Содержание 105 Series II
Страница 6: ...V ...
Страница 14: ...XIII Figure 2 Demo Board Non conductive surface ...
Страница 15: ...XIV 91 92 96 99 105 Users Manual ...
Страница 17: ...XVI 91 92 96 99 105 Users Manual ...
Страница 204: ...10 34 91 92 96 99 105 Users Manual Figure 10G 5 EXT mV menu MORE EXT mV ALERT ZERO FAST SMOOTH RESET READING ...
Страница 205: ...Appendixes 10 35 Figure 10G 6a MEASURE menu MORE MEASURE V dB TIME Hz See Figure 10G 6b ...
Страница 206: ...10 36 91 92 96 99 105 Users Manual Figure 10G 6b MEASURE menu MORE MEASURE V dB TIME Hz See Figure 10G 6a ...
Страница 212: ...10 42 91 92 96 99 105 Users Manual Figure 10G 13 SPECIAL FUNCTION menu MENU TEST MENU GENERATE MATH COMP 92 91 96 ...