17. Which of the following statements is true
regarding use of the APU for electrical
power?
A. The APU can be used to power the
electrical system on the ground in
conjunction with an airplane engine
generator.
B. The APU can be used inflight with
one or both generators operating.
C. The APU and a GPU can be used at the
same time.
D. The APU and a GPU cannot be used
at the same time, the APU will take
precedence.
18. In flight, at what amperage will the amp
display on the EICAS SUMRY page
change color to amber?
A. 275
B. Above 300
C. Above 400
D. 450
19. If the left generator fails inflight, what
will the left essential VOLTS show on
the EICAS SUMRY page?
A. Zero volts will be displayed.
B. It will show emergency battery volt-
age.
C. It will show voltage of the operating
generator.
D. It will show red dashes to indicate the
generator has failed.
20. What indication(s) will the crew have of
a generator failure?
A. The Master Caution lights will flash.
B. An “OFF” annunciation will illumi-
nate on the corresponding generator
switch.
C. A flashing amber L or R GEN FAIL
message will appear on the CAS.
D. All of the above.
L E A R J E T 4 5
P I L O T T R A I N I N G M A N U A L
2-43
FOR TRAINING PURPOSES ONLY
FlightSafety
international