CAS messages, alerting the crew to system
failure, faults or overheating.
The windshield anti-ice/defog system is se-
lected on by depressing the L and R WSHLD
switch/indicators (S/Is) located on the anti-ice
control panel (Figure 10-2). When the sys-
tems are off, an OFF caption is illuminated on
each S/I. When selected on, each S/I is blank,
with no caption illuminated.
During normal operation the controller regu-
lates the output of the alternators to maintain
the windshield temperature between 80° and
110° F. If there is a fault in the circuitry for
normal operation, the system can continue to
operate in a degraded mode. In the degraded
mode the output of the alternator is no longer
modulated and the controller cycles power
full on to the windshield at 70° F and off at
125° F. The controller continues to cycle power
on and off between these values when oper-
ating in the degraded mode. A “L or R WSHLD
HT FAULT” message is displayed on CAS
10-7
FOR TRAINING PURPOSES ONLY
L E A R J E T 4 5
P I L O T T R A I N I N G M A N U A L
FlightSafety
international
W = Warning
C = Caution
A = Advisory
CAS Message
Logic Summary
Type
Msg
W
C
C
C
C
C
C
C
C
C
W
W
A
A
C
C
C
WING/STAB LEAK
Leak detected ( > 255
°
F) in wing or stab supply lines
STAB OVHT
WING OVHT
AOA vane heater failed w/probe heat ON
ICE DET FAIL
ICE DETECTED
Ice detect system failed
L R AOA HT FAIL
Ice detected, Anti-Ice systems OFF, (ground suppressed)
L R NAC HT
L R NAC HT FAIL ON
L R PITOT HT
L R WSHLD OVHT
L R WSHLD HT FAIL
L R WSHLD HT FAULT
NAC SW ON, low pressure, or Pt
2
Tt
2
probe heat failed
NAC switch off, pressure on
Probe heat OFF or pitot heat failed
SAT HT FAIL
SAT/TAT probe heat failed w/right probe heat ON
STAB TEMP LOW
Anti-Ice ON, stab underheated, > 10 seconds
STBY PITOT HT
WING TEMP LOW
ICE DETECTED
Standby (right) probe heat OFF or failed
Anti-Ice ON, wing underheated, > 10 seconds
L, or R, or both windshield overheated ( > 160
°
F)
L, or R, or both windshield heat ON, system failed/under-temp ( < 50
°
F)
Ice detected, Anti-Ice systems ON, (ground suppressed)
A
A
STAB TMP FAULT
WG/STAB HT OK
Stab sensor failed, or HI or LOW temp sensor invalid
Ground test of wing/stab heat system OK (checks discretes)
A
WING TMP FAULT
Wing sensor failed, or HI or LOW temp sensor invalid
L, or R, or both windshield heat ON, degraded operation
Stab ovht, does not auto shutdown
Wing ovht, does not auto shutdown
Table 10-1. ICE AND RAIN PROTECTION CAS MESSAGE DATABASE