8. After the new board is installed, address it for the appropriate tank position:
•
Place catch container under the Product Dispensing Block
•
Locate the Reverse Button on the left side of the driver board and the
Forward Button on the right side of the driver board.
•
Press and hold the right (Forward) button first and then the left (Reverse)
button – the Status Light in the upper right corner will blink.
The Status Light will blink: 1 blink – 1-second pause – 2 blinks – 1-
second pause – 3 blinks – 1-second pause, in sequence to cover all ten
flavor tanks.
NOTE:
the pump plunger may move slightly, releasing flavor. Use
catch container.
•
Count the blinks and release the buttons
after
the number of blinks for the
tank number of the driver board you are replacing, e.g. after 1 flash for
tank 1, after 5 flashes for tank 5.
•
One second later, the Status Light will blink the number of your tank – to
verify the tank number that you have just programmed.
9. Turn the dispenser OFF and then turn the dispenser back ON.
10. Prime the pump. See page 9.
11. For alternative method, see “Pump Assembly – Addressing position” below.
Pump Bank
Содержание AC-FS5
Страница 1: ...AC FS5 Service Manual D 19 022...
Страница 27: ...27 Tanks Removal...
Страница 41: ...41 IV DRAWINGS WIRING DIAGRAM...
Страница 42: ...42 Shelf Assembly FlavorShot 5...
Страница 43: ...43 Tubing Clear PVC Assembly FlavorShot 5...
Страница 44: ...44 Outer Body Assembly FS 5...
Страница 45: ...45 General Assembly FS 5...