321023
51
8.2.2
Evaporator Fan Does Not Turn On
Yes
Yes
Yes
No
No
No
Is the problem
fixed?
Use Service Test
112 to turn
evaporator fan on.
Does the fan
run?
Replace HV box
assembly
12872238.
Does RF
display read
a number
> 11?
Ensure connector
J3 is properly
connected to the
main control
board.
Check continuity
of FZ liner harness
and HV PCB
harness. Replace
as necessary.
Replace
evaporator fan.
Done.