321023
94
13.3 Refrigerant
Precautions
WARNING
To avoid risk of personal injury, do not allow refrigerant to contact eyes or skin.
CAUTION
To avoid risk of property damage, do not use refrigerant other than as shown on unit serial
number identification plate.
NOTE:
All precautionary measures recommended by refrigerant manufacturers and suppliers apply
and should be observed.
13.4
Line Piercing Valves
Line piercing valves can be used for diagnosis, but are not suitable for evacuating or charging due to
holes pierced in tubing by valves.
NOTE:
Do not leave line piercing valves on system. Connection between valve and tubing is not
hermetically sealed. Leaks will occur.
13.5 Open
Lines
During any processing of refrigeration system, never leave lines open to atmosphere. Open lines
allow water vapour to enter system, making proper evacuation more difficult.
13.6
Compressor Operational Test
(Short term testing only)
If compressor voltage, capacitor, overload, and motor winding tests are successful (do not indicate a
fault), perform the following test:
1. Disconnect power to unit.
2. Discharge capacitor by shorting capacitor terminals through a resistor.
NOTE:
Not all units have run capacitor.
3. Remove leads from compressor terminals.
4. Attach test cord to compressor windings.
•
Common lead on test cord attaches to C terminal on compressor.
•
Start lead on test cord attaches to S terminal on compressor.
•
Run lead on test cord attaches to M terminal on compressor.
Attaching Capacitor for Compressor Test
5. Connect a known good capacitor into circuit as shown above. For proper capacitor size and
rating, see technical data sheet for unit under test.
Содержание RX256DT4X1
Страница 11: ...321023 11 2 3 Refrigerant Flow...
Страница 12: ...321023 12 2 4 Cabinet Air Flow...
Страница 13: ...321023 13 2 5 Ice And Water Dispenser Diagram...
Страница 14: ...321023 14 2 6 Water Valve Diagram...
Страница 15: ...321023 15 2 7 Typical External Sweat Pattern...
Страница 16: ...321023 16 3 INSTALLATION...
Страница 17: ...321023 17...
Страница 18: ...321023 18...
Страница 76: ...321023 76 Ice Water Dispensing Board...
Страница 78: ...321023 78 Mid Electronic Specification Control RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 104: ...321023 104 14 WIRING DIAGRAMS 14 1 Wiring Schematic RX256DT7X1...
Страница 105: ...321023 105 14 2 Wiring Diagram RX256DT7X1...
Страница 106: ...321023 106 14 3 Wiring Schematic RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 107: ...321023 107 14 4 Wiring Diagram RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 108: ...321023 108 NOTES...