321023
52
8.2.3
Damper Does Not Move
Use Service Test
121 to open the
damper.
Does the
damper move?
Make sure
connector J3 is
properly
connected on the
main board.
Is there line
voltage?
While Service Test
121 is displaying
OPEN for damper
state, measure
voltage across pin
3 and pin 9 on J3
connector.
Check continuity
of FZ liner harness
and HV PCB
harness. Replace
as necessary.
Replace HV box
assembly
12872238.
Check damper
wiring connection.
Replace damper.
Yes
No
Yes
No