321023
38
DEFROST
THERMOSTAT
OPEN
DEFROST
THERMOSTAT
CLOSED
8.1.4.3
Service Test 102 - Compressor/Condenser System.
When selected and activated, this test will operate the compressor/condenser fan circuit. A service
technician should evaluate proper operation of the compressor and condenser fan. The Refrigerator
Temperature Up/Down keypads
/
will toggle the compressor drive circuit between "On" and
"Off".
OBSERVE COMPRESSOR & CONDENSER FAN FUNCTION
8.1.4.4
Service Test 112 - Freezer Fan Operation.
When selected and activated, this test will operate the freezer fan (evaporator fan). The Refrigerator
Temperature Up /Down keypads
/
will toggle the fan drive circuit between on and off. The
technician will have to inspect the fan for proper function.
•
The refrigerator display will show the voltage level supplied to the fan. When on, the refrigerator
display will show a voltage reading between 11.0 to 14.0 volts. When off, the refrigerator display
will show a voltage reading of 0.0 volts.
EVAPORATOR FAN IS OFF
EVAPORATOR FAN IS ON
Содержание RX256DT4X1
Страница 11: ...321023 11 2 3 Refrigerant Flow...
Страница 12: ...321023 12 2 4 Cabinet Air Flow...
Страница 13: ...321023 13 2 5 Ice And Water Dispenser Diagram...
Страница 14: ...321023 14 2 6 Water Valve Diagram...
Страница 15: ...321023 15 2 7 Typical External Sweat Pattern...
Страница 16: ...321023 16 3 INSTALLATION...
Страница 17: ...321023 17...
Страница 18: ...321023 18...
Страница 76: ...321023 76 Ice Water Dispensing Board...
Страница 78: ...321023 78 Mid Electronic Specification Control RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 104: ...321023 104 14 WIRING DIAGRAMS 14 1 Wiring Schematic RX256DT7X1...
Страница 105: ...321023 105 14 2 Wiring Diagram RX256DT7X1...
Страница 106: ...321023 106 14 3 Wiring Schematic RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 107: ...321023 107 14 4 Wiring Diagram RX256DT4X1 RX256ET2B1 RX256ET2W1...
Страница 108: ...321023 108 NOTES...