9
ORDERING INFORMATION
Control
PPC4000
Parallel positioning system, 120 VAC input. Used with flame safeguard control.
PPC4000-230V
Parallel positioning system, 230 VAC input. Used with flame safeguard control.
NXCESVFD
Plug-in assembly provides variable frequency (VFD/VSD) capability
60-2926
Enclosure, 12.5” x 10.5” x 6.5”, UL listed, fitted for PPC4000
129-190
Kit, fan replacement
Display
NXD410
User Interface with keypad, 24 VDC operation, 4 line back lit LCD display, panel mount only, includes mounting brack-
ets.
59-562-2
Cable assembly, 10 feet length, for interfacing NXD410 to PPC4000
NXTSD407/NXTSD413
7” TFT or 13.3” wide color Touchscreen display, 800x480 or 1280x800 pixel (WVGA) resolution, LED backlight, 24VDC,
includes mounting brackets
129-196-2
Replacement cable kit. Contains one 12’ communications, one 12’ power cable, and DB9 connector plug.
Servos
FX04
Servo motor, 24 VDC operation, 4Nm, 3 lb.-ft. torque,
without
connectors, accepts 1/2 inch NPT fitting, minimum travel
time of 30 seconds for 90°
FX04-1
Servo motor, 24 VDC operation, 4Nm, 3 lb.-ft. torque,
with
connectors, minimum travel time of 30 seconds for 90°
FX20
Servo motor, 24 VDC operation, 20Nm, 15 lb.-ft. torque,
without
connectors, accepts
1/2 inch NPT fitting, minimum travel time of 30 seconds for 90°
FX20-1
Servo motor, 24 VDC operation, 20Nm, 15 lb.-ft. torque,
with
connectors, minimum travel time of 30 seconds for 90°
FX50
Servo motor, 24 VDC operation, 50Nm, 37 lb.-ft. torque,
without
connectors, accepts
1/2 inch NPT fitting, minimum travel time of 30 seconds for 90°
FX50-1
Servo motor, 24 VDC operation, 50Nm, 37 lb.-ft. torque,
with
connectors, minimum travel time of 30 seconds for 90°
Servo Cables
59-565-6
Cordset, 6 feet, 1/2” NPT connectors on both ends, PVC jacket, temperature rating -40°C to 105°C, meets NEMA
1,3,4,6P and IEC67
59-565-40
Cordset, 40 feet, 1/2” NPT connectors on both ends, PVC jacket, temperature rating -40°C to 105°C, meets NEMA
1,3,4,6P and IEC67
Connector Kit
129-192
Connector, field wireable. Used for FX04-1, FX20-1, FX50-1 servos with connectors. Use cable 59-565
129-194
Male quick disconnect to convert non connector type FX series servos.
59-565
Cable, 1 twisted pair, 2 power wires, suitable for servo and Oxygen probe hookup.
O2 Probe
NXCESO2-8, -16, -30
O2 probe assembly, insertion length is 8, 16, 30 inches
NXCESO2-8,-16,- 30-KIT O2 probe assembly kit includes NXCESO2 probe, 35-381-2 flange and FXIATS-140 sensor
NXCES02P42, -1
Cartridge, probe replacement (model -1 for engineering code 00 only)
35-381-2
Flange, O2 probe mounting
129-189
Cover, mounting flange
Pressure Transducers
BLPS-15, -25, -30
Pressure transducer, 0 to15 PSI (0 to 1030 mb), -14.7 to 25 PSI (-1013 to 1720 mb), 0 to 30 PSI (0 to 2070 mb), 4-20
mA output linear with pressure. ¼” NPTF mounting. Screw terminal connections and conduit adapter cover.
BLPS-200
Pressure transducer, 0 to 200PSI (0 to 13.8 Bar), 4-20 mA output linear with pressure. ¼” NPTF mounting. Screw
terminal connections and conduit adapter cover.
BLPS-300
Pressure transducer, 0 to 300 PSI (0 to 20.7 Bar), 4-20 mA output linear with pressure. ¼” NPTF mounting. Screw
terminal connections and conduit adapter cover.
Temperature Transducers
TS350-2, -4, -8
Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 4-20 mA output, linear with temperature. Insertion length is
2, 4, 8 inches. Stainless steel thermowell included.
TS-752-2, -4, -8
Temperature sensor, Range 32°F to 752°F (0°C to 400°C), 4-20 mA output, linear with temperature. Insertion length is
2, 4, 8 inches. Stainless steel thermowell included.
FXIATS-140
Ambient air temperature transmitter, -40°F to 140°F, 4-20mA output, 7 to 40VDC, NEMA enclosure