
7-76
•
Remove and clean (replace if neces-
sary) the filter.
7.4.4-22 Recovery
Tank
Lid
7.4.4-23 Filter Cup
7.4.4-24 Ball Filter
7.4.5
Recovery Tank
Checks
The recovery tank has to be clean and
has not to have cracks or, in general, any
kind of damage. The Lid housing has to
be even and flat to allow the gasket to ad-
here perfectly to the tank to avoid any air
infiltration. The hose fittings have to be
in optimum condition in order to avoid
any dirty water leakage or any pressure
drop during the job.
7.4.6
Vacuum Motor
Checks
The vacuum motor with the inlet com-
pletely open has to absorb between 13
and 18A. The motor carbon brushes
have to be in good conditions and their
length has to be no lower than 6-8mm.
The motor contacts have to be clean,
they have not to be oxidized or have any
kind of damage. The motor wires insula-
tion has to be flexible and intact to avoid
7.4.5-25 Vacuum Cover
7.4.5-26 Recovery Tank
7.4.5-27 Vacuum Hose
7.4.5-28 Vacuum Hose
7.4.5-29 Drain Hose
any possible short circuit. The magnetic
circuit of the motor has to be in good
conditions and clean.
Maintenance
•
Put the machine in safe conditions.
•
Disassemble the motor from the ma-
chine
(see section
4.3.10
at page
29
)
.
•
Remove the cooler fan plastic cover
from the motor
(see fig.
7.4.6-30
)
.
7.4.6-30 Plastic cover re-
moval
Содержание IMx
Страница 1: ...WORKSHOP HANDBOOK IMx Version AB Date October 29 2013 Document Number 10043430 ATE ...
Страница 9: ...Part I Product Introduction 9 ...
Страница 12: ...2 12 Part II Anomalies Resolution Guide 12 ...
Страница 43: ...4 43 Part III Machine Description 43 ...
Страница 46: ...5 46 5 5 Location of Electrical components 5 5 1 IMx BB ...
Страница 48: ...5 48 5 5 2 IMx B BT ...
Страница 87: ...9 87 Part IV Accessories and Add On 87 ...
Страница 93: ...10 93 10 5 Consumable Spare Parts iMx PN Description BB B BT 438058 SPLASHGUARD BAS L 1406 H 75 IMX 50 ...