5-62
General Sets
MENU
DEFAULT
VALUES
DESCRIPTION
General Sets:
Language: ##
IT
IT-EN-FR-SP
Setup the language of the display.
General Sets:
Mode: ##
IMX-BT
IMX B - IMX
BT
Setup of the machine model (Normal version or with dosing
system).
General Sets:
Battery: ##
GEL
GEL-WET-
AGM-GE1-
WE1
Setup of the battery type.
General Sets:
Rst.Cnthr: ##
N
Reset partial hourmeter (like on “working menu”).
General Sets:
Rst.Main Cnthr: ##
N
Reset total hourmeter (key, brush, vacuum, traction).
Brushes Sets
Parameter
Default
Min
÷
Max
Description
Brushes Sets:
I Max: ## [Amp]
40
20
÷
50
Maximum current from the main card to the brush motor.
Brushes Sets:
I Nom: ## [Amp]
25
10
÷
40
Rated current; with T Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
T Nom: ## [s]
30
1
÷
60
Rated timer; with I
Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
T Off: #.# [s]
0.0
0.0
÷
10.0
Delay of switching off of the brush motor when the safety lever is
released.
Brushes Sets:
T Reset: ## [s]
10
0
÷
100
Timing of reset amperometric protection (overcurrent) - NOT USED.
Brushes Sets:
T On: #.# [s]
0.2
0.0
÷
5.0
Delay to switching on of the brush motor when the safety lever is
pressed.
Brushes Sets:
Eco Speed: ## [V]
17
15
÷
20
Value of Voltage reduction of brush motor, during ECO mode.
Содержание IMx
Страница 1: ...WORKSHOP HANDBOOK IMx Version AB Date October 29 2013 Document Number 10043430 ATE ...
Страница 9: ...Part I Product Introduction 9 ...
Страница 12: ...2 12 Part II Anomalies Resolution Guide 12 ...
Страница 43: ...4 43 Part III Machine Description 43 ...
Страница 46: ...5 46 5 5 Location of Electrical components 5 5 1 IMx BB ...
Страница 48: ...5 48 5 5 2 IMx B BT ...
Страница 87: ...9 87 Part IV Accessories and Add On 87 ...
Страница 93: ...10 93 10 5 Consumable Spare Parts iMx PN Description BB B BT 438058 SPLASHGUARD BAS L 1406 H 75 IMX 50 ...