
5-63
Pumps Sets
Parameter
Default
Min
÷
Max
Description
Pumps Sets:
Wtr Lev1: ### [V]
10.0
5
÷
24
First level of water flow of the proportional solenoid valve.
Pumps Sets:
Wtr Lev2: ### [V]
11.0
5
÷
24
Second level of water flow of the proportional solenoid valve.
Pumps Sets:
Wtr Lev3: ### [V]
13.5
5
÷
24
Third level of water flow of the proportional solenoid valve.
Pumps Sets:
Wtr Lev4: ### [V]
16.0
5
÷
24
Fourth level of water flow of the proportional solenoid valve.
Pumps Sets:
Wtr Lev5: ### [V]
20.0
5
÷
24
Fifth level of water flow of the proportional solenoid valve.
Vacuum Sets
Parameter
Default
Min
÷
Max
Description
Vacuum Sets:
I Max: ## [Amp]
40
10
÷
40
Maximum current from the main card to the vacuum motor.
Vacuum Sets:
I Nom: ## [Amp]
20
5
÷
25
Rated current; with T Nom manages the amperometric protection
(alarm + stop vacuum motor).
Vacuum Sets:
T Nom: ## [s]
10
1
÷
10
Rated timer; with I Nom manage the amperometric protection (alarm
+ stop vacuum motor).
Vacuum Sets:
T Off: ## [s]
5
0
÷
30
Delay of switching on of the vacuum motor when the switch is
pressed.
Vacuum Sets:
T Off stop: ## [s]
15
0
÷
100
Delay of switching off of the vacuum motor when the safety lever is
released
Vacuum Sets:
Eco Speed: ## [V]
17
15
÷
20
Value of Voltage reduction of vacuum motor, during ECO mode
Содержание IMx
Страница 1: ...WORKSHOP HANDBOOK IMx Version AB Date October 29 2013 Document Number 10043430 ATE ...
Страница 9: ...Part I Product Introduction 9 ...
Страница 12: ...2 12 Part II Anomalies Resolution Guide 12 ...
Страница 43: ...4 43 Part III Machine Description 43 ...
Страница 46: ...5 46 5 5 Location of Electrical components 5 5 1 IMx BB ...
Страница 48: ...5 48 5 5 2 IMx B BT ...
Страница 87: ...9 87 Part IV Accessories and Add On 87 ...
Страница 93: ...10 93 10 5 Consumable Spare Parts iMx PN Description BB B BT 438058 SPLASHGUARD BAS L 1406 H 75 IMX 50 ...