5-57
Charging curve SetUp
To set up the charger, follow the instruc-
tions:
•
Use a screwdriver to remove the
small black plastic cap
•
Set-up the internal dipswitches ac-
cording to the following table
The dipswitches are divided in two cou-
ple.
The higher couple are the dip-
switches 1 and 2, the couple down are
the dipswitches 3 and 4.
The follow-
ing table shows how to setup the dip-
switches 1 and 2
Set-up of Charging Curve
DP1 DP2 Set-up
Flash
OFF OFF Wet cell batteries
1
ON
ON
Gel TROJAN
2
OFF ON
Generic
GEL
or
AGM batteries
3
ON
OFF Gel EXIDE SON-
NENSCHEIN
4
DP3: OFF (not used)
DP4: OFF (not used)
Restore the the small black plastic cup.
Error Codes of Charger
The charger have an alarm system. The
alarm code is shown by blinks of the yel-
low led.
Error code
Flash
Description
1
Wrong battery, Inverted polarity,
short circuit to the exit
2
Timeout alarm, Defect of the bat-
tery
3
Defect of the Charger
4
Overtemperature alarm
5.11.3
ECO Function (solo IMx
B/BT)
Press the ECO button, and let the vac-
uum motor and the brush motor work.
with the ECO mode activated, check if
the noise of the vacuum motor and the
brush motor is reduced.
Connect an
Amperometric to the positive cable of the
batteries and check if the current con-
sumption is less than normal function
(without ECO mode).
ATTENTION.
We
don’t give the amperometric values be-
cause it can change depending of the
working conditions.
Содержание IMx
Страница 1: ...WORKSHOP HANDBOOK IMx Version AB Date October 29 2013 Document Number 10043430 ATE ...
Страница 9: ...Part I Product Introduction 9 ...
Страница 12: ...2 12 Part II Anomalies Resolution Guide 12 ...
Страница 43: ...4 43 Part III Machine Description 43 ...
Страница 46: ...5 46 5 5 Location of Electrical components 5 5 1 IMx BB ...
Страница 48: ...5 48 5 5 2 IMx B BT ...
Страница 87: ...9 87 Part IV Accessories and Add On 87 ...
Страница 93: ...10 93 10 5 Consumable Spare Parts iMx PN Description BB B BT 438058 SPLASHGUARD BAS L 1406 H 75 IMX 50 ...