3.2
Dismantling and mounting CMAX
The CMAX is mounted in an interlinking block (
è
Section 4.4) of the CPX terminal (
è
Note
Damage to the product from incorrect handling.
Switch off the supply voltage before mounting and installation work. Switch on sup
ply voltage only when mounting and installation work are completely finished.
Never push/pull the electronics module into/out of the interlinking block when un
der power!
Note
The CMAX contains electrostatically sensitive devices. Electrostatic discharge caused by
improper handling or incorrect earthing can damage components.
Do not touch any components.
Observe the handling specifications for electrostatically sensitive devices.
Dismantling CMAX
1. Switch off the operating and load voltage supplies.
2. Unscrew 4 CMAX screws using a TORX screwdriver, size T10.
3. Pull CMAX carefully and without tilting away from the contact rails of the interlinking block.
1
2
3
4
1
CMAX
2
Interlinking block
3
Contact rails
4
Torx T10 screws
Fig. 3.2
Dismantling/mounting the CMAX