Group 7 − Controller error
CPX error group 107
(CPX-MMI: [Controller error] )
No.
Reset type
Error level
Message
74
No firmware
FS
Poff
Cause
No firmware. No communication possible via fieldbus.
Measure
Firmware download with FCT.
75
User data damaged
F2
N
Cause
Inconsistent user data.
Measure
Perform data reset and re-commission the axis.
76
Unexpected restart: Possible data loss
F2
N
Cause
The CMAX was restarted unexpectedly; the user data could not be saved.
Measure
Check whether the user data is complete and correct.
Check whether the CMAX is subjected to strong electromagnetic
interference, and eliminate this.
Contact Support.
77
Firmware damaged
FS
Poff
Cause
Checksum fault Firmware
Measure
Download Firmware.
Contact Support.
Group 8 – Displacement encoder error
CPX error group 108
(CPX-MMI: [Encoder error] )
No.
Message
Error level Reset type
80
Displacement encoder not connected or communication faulty
F2
N
Cause
Displacement encoder/sensor interface was not detected when switching on.
Measure
Replace position measuring system/sensor interface; check the cables.
Cause
Communication between CMAX and displacement encoder/sensor interface is
faulty.
Measure
Check cables of the axis string, valve and displacement encoder/sensor
interface systematically; replace if defective.
81
Hardware of the displacement encoder or sensor interface faulty
F2
N
Cause
Hardware of the displacement encoder or sensor interface defective.
Measure
Replace displacement encoder/sensor interface.
Cause
Fault during initialization of the displacement encoder/sensor interface.
Measure
Replace displacement encoder/sensor interface.
Check compatibility of the displacement encoder/sensor interface with the
firmware version of the CMAX.