![Festo CPX-CMAX Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/festo/cpx-cmax/cpx-cmax_description_2283162030.webp)
3
Mounting and pneumatic installation
30
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English
3.4.2
Mounting the VPWP proportional directional control valve
Attach the VPWP as close to the drive as possible according to one of the following alternatives.
VPWP-4/-6/-8
a) Mounting on an even surface with two M3 screws and
one retaining washer each
The tightening torque is 1.5 N ±10 %.
Fig. 3.4
b) Mounting on the side with 4 M4 screws
The tightening torque is 3 Nm ±10 %.
Fig. 3.5
c) Mounting to an H-rail (DIN mounting rail size TH35)
Depending on the size of the VPWP, the following attach
ment is required (
è
www.festo.com/catalogue):
–
VPWP-4/-6: CPASC1-BG-NRH
–
VPWP-8:
CPV10/14-VI-BG-NRH-35
1. Ensure that the mounting surface can carry the weight
of the VPWP.
2. Mount H-rail. Be sure to leave sufficient space for con
necting the supply cables and tubes.
1
2
Fig. 3.6
3. Screw mounting clips to the VPWP with the accompanying screws – tightening torque 1.5 Nm. Make
sure that the fixing bolts (
1
) of the clips grip into the groove of the VPWP.
4. Hang the VPWP on the H-rail. Secure against tipping or slipping by using the H-rail clamping (
2
).