![Festo CPX-CMAX Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/festo/cpx-cmax/cpx-cmax_description_2283162085.webp)
6
Diagnostics and error handling
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English
85
Group 8 – Displacement encoder error
CPX error group 108
(CPX-MMI: [Encoder error] )
No.
Reset type
Error level
Message
82
Invalid measured values or displacement encoder faulty
F2
F
Cause
DGCI/DDLI: No magnet present.
Measure
Check magnet on the displacement encoder, replace magnet holder if
defective.
Cause
DGCI/DDLI: Several magnets present.
Measure
Make sure that no external magnets are in close proximity to the
displacement encoder.
Cause
DGCI/DDLI: Multiple pulses (e.g. due to vibrations).
Measure
Check mounting.
Avoid vibration.
Cause
DNCI: Sensor error.
Measure
Replace sensor head in the DNCI.
Cause
Potentiometer: Operating voltage drop below 12 V.
Measure
Check operating voltage, check cables for short circuit and corrosion.
84
Reference position of the displacement encoder lost
F2
N
Cause
Although the drive has set the status “Referenced”, the displacement encoder/
sensor interface reports the status “Not referenced”.
Measure
Reference again.
85
Operating voltage of displacement encoder/sensor interface
outside the tolerance range
F2
F
Cause
Operating voltage of the displacement encoder too low.
Measure
Check power supply.
Check lines on the axis string.
87
Defective displacement encoder cable or potentiometer in
electrical end position
F2
N
Cause
Defective displacement encoder cable.
Measure
Check power supply.
Check lines on the axis string.
Switching off/on may be required.
If this occurs repeatedly, replace the displacement encoder or sensor
interface.
Cause
Displacement encoder in the electrical end position (potentiometer only).
Measure
Move displacement encoder (potentiometer) from the end position.