4.2 Locating faults
Malfunctioning
When you switch on the compressed air supply or test
the individual valves, you can learn the following about
the operating status of the pneumtic system:
Operating status of the
pneumatic system
Valve position
Error treatment when compressed
air supply has beeen switched off
Air comes out...
– at common line
connections
– at work line
connections
– between the modules
– Basic position
– Switch position
– Basic position
•
Check the tubing
•
Check the tubing
•
After switching on, regulate
external pilot air to 3 to 8 bar
Valve or pneumatic system
– does not react as expected
– does not react
– does not react
– Switch position
– Switch position
– Switch position
•
Check tubing
•
After switching on,
check operating pressure
(e.g. pressure zones)
•
Place locking manual override in
basic position
•
In the case of CPA valve terminals
with 3/2-way valves, check external
pilot air (or set as a factor of
working pressure)
•
Servicing required
•
Check regulator (apply pressure
>3 bar to regulator )
4. Commissioning
CPA... 9808A
4-11
Содержание CPA VI Series
Страница 2: ......
Страница 4: ...Order no 173 515 Title MANUAL Designation P BE CPA GB II CPA 9808A...
Страница 15: ...Chapter 1 System summary 1 System summary CPA 9808A 1 1...
Страница 29: ...Chapter 2 Fitting 2 Fitting CPA 9808A 2 1...
Страница 35: ...Kapitel 3 Installation 3 Installation CPA 9808A 3 1...
Страница 54: ...3 Installation 3 20 CPA 9808A...
Страница 55: ...Chapter 4 Commissioning 4 Commissioning CPA 9808A 4 1...
Страница 69: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPA 9808A 5 1...
Страница 97: ...Technical appendix A Technical appendix CPA 9805NH A 1...