3.2.3 Connecting the supply, exhaust and work lines
Fit the screw connectors as described below. Then con-
nect the tubing.
Proceed as follows:
1. Use the table below in order to select the correct
pin-type inserts.
Connec-
tion code
ISO 5599
Line
CPA10 terminal
pin-type size
CPA14 terminal
pin-type size
1
3/5
With
threaded
connection
also
connec-
tions 12/14
and 82/84
Com-
pressed
air/
vacuum,
exhaust
Tube connection:
QSP14-6
QSP14-8
QSP14-1/4-U
QSP14-5/16-U
Blind plug:
QSP14-PTB
Threaded connection:
CPA10-PTE-1/8-M5
CPA10-PTE-1/8NPT-10-32-UNF
Blind screw:
B-1/8
B-1/8NPT
Tube connection:
QSP18-8
QSP18-10
QSP18-5/16-U
QSP18-3/8-U
Blind plug:
QSP18-PTB
Threaded connection:
CPA14-PTE-1/4-M5
CPA14-PTE-1/4NPT-10-32-UNF
Blind screw:
B-1/4
B-1/4NPT
2 or 4
12/14
82/84
With
CPA14
terminal:
values in
brackets
for 12/14
resp.
82/84
with
threaded
connection
not 12/14
resp. 82/84
Work air/
vacuum,
additional
pressure
supply,
exhaust
pilot air
Tube connection:
QSP10-4
QSP10-6
QSP10-5/32-U
QSP10-3/16-U
Blind plug:
QSP10-PTB
Threaded connection:
CPA10-PTA-M5
CPA10-PTA-M7
CPA10-PTA-10-32-UNF
Blind screw:
B-M5-B
B-M7 (only connection 2/4)
Tube connection:
QSP14-6 (QSP10-4)
QSP14-8 (QSP10-6)
QSP14-1/4-U (QSP10-5/32-U)
QSP14-5/16-U (QSP10-3/16-U)
Blind plug:
QSP14-PTB (QSP10-PTB)
Threaded connection:
CPA14-PTA-1/8
CPA14-PTA-1/8NPT
Blind screw:
B-1/8
(B-M5-B)
B-1/8N
3. Installation
CPA... 9808A
3-11
Содержание CPA VI Series
Страница 2: ......
Страница 4: ...Order no 173 515 Title MANUAL Designation P BE CPA GB II CPA 9808A...
Страница 15: ...Chapter 1 System summary 1 System summary CPA 9808A 1 1...
Страница 29: ...Chapter 2 Fitting 2 Fitting CPA 9808A 2 1...
Страница 35: ...Kapitel 3 Installation 3 Installation CPA 9808A 3 1...
Страница 54: ...3 Installation 3 20 CPA 9808A...
Страница 55: ...Chapter 4 Commissioning 4 Commissioning CPA 9808A 4 1...
Страница 69: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPA 9808A 5 1...
Страница 97: ...Technical appendix A Technical appendix CPA 9805NH A 1...