3.2.2 CPA valve terminal with separation of pressure zones
The CPA valve terminal can be fitted with the following
number of pressure zones, depending on the con-
nection variant:
Electrical connection
variant
IC or MP
CP
AS-i
Number of pressure zones
1 - 12
1 - 9
1 - 3
The pressure zones are implemented by means of
special sub-bases which block the compressed air
channel (1).
Valves plates fitted onto sub-bases with separate press-
ure zones are operated with compressed air which is
supplied on the left-hand side of this sub-base (see Fig.
3/5). The number of pressure zones with which your
CPA valve terminal is equipped is indicated on the
special sub-base (grey point above work connection 2).
CPA valve terminals with two pressure zones
These CPA valve terminals have a sub-base with sep-
aration of the pressure zones. The left-hand pressure
zone is supplied with compressed air via connection 1
on the left-hand end plate; the right-hand pressure zone
is supplied with compressed air via connection 1 on the
right-hand end plate.
3. Installation
CPA... 9808A
3-9
Содержание CPA VI Series
Страница 2: ......
Страница 4: ...Order no 173 515 Title MANUAL Designation P BE CPA GB II CPA 9808A...
Страница 15: ...Chapter 1 System summary 1 System summary CPA 9808A 1 1...
Страница 29: ...Chapter 2 Fitting 2 Fitting CPA 9808A 2 1...
Страница 35: ...Kapitel 3 Installation 3 Installation CPA 9808A 3 1...
Страница 54: ...3 Installation 3 20 CPA 9808A...
Страница 55: ...Chapter 4 Commissioning 4 Commissioning CPA 9808A 4 1...
Страница 69: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPA 9808A 5 1...
Страница 97: ...Technical appendix A Technical appendix CPA 9805NH A 1...