ISO 15693 OPTION:
(Transponder.HF.ISO_15693.Miscellaneous.WriteOption)
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
WR-OPTION
0
0
WR-OPTION:
b00:
automatically set
b10:
Tag Option = 0
b11:
Tag Option = 1
Note:
•
If WR-OPTION is automatically set, the Reader sets the WR-OPTION to 0, if the ISO15693
Host Command is in non-addressed mode
ISO-Read-Option:
Bit:
7
6
5
4
3
2
1
0
Function
Read Mode
Blocksize
Selection
Blocksize
Blocksize: (Transponder.HF.ISO_15693.Miscellaneous.ReadOption.BlockSize)
Defines the block size of an ISO-transponder which is not listed in the MFR-table
(see:
9.2. Supported ISO Host commands for
) or if
the transponder is used in the non-addressed mode.
Range: 0x01 ... 0x1F
A value of 0x00 will be automatically set to a block size of 4byte.
Blocksize Selection: (Transponder.HF.ISO_15693.Miscellaneous.ReadOption.
BlockSizeSelection)
b0:
Automatic (If transponder is known)
b1:
Manuel (As specified in DB-Blocksize)
Read Mode: (Transponder.HF.ISO_15693.Miscellaneous.ReadOption.ReadMode)
b00:
Automatic Mode (If transponder is known)
b01
Single Read
b10
Multiple Read
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...