4.4. CFG3: RF-Interface HF
The parameters of the CFG3 configuration block contain global Transponder drivers and Reader
settings for HF.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
0x00
0x00
0x00
0x00
0x00
Default
0x0008
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
TAG-DRV
1
: (Transponder.Driver.HF.Drivers)
Defines the Transponder types that are operated by the Reader.
Byte:
0
1
Bit:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
0
0
0
0
0
0
.D
0
0
0
b0
⇒
Driver for the Transponder type is inactive
b1
⇒
Driver for the Transponder type is active
.D: (Transponder.Driver.HF.ISO_15693)
Driver for ISO15693 In principle, only those Transponder drivers should
be active that are used in the actual application. Thus, the reaction time of the
Reader for Transponder read- / write-operations is reduced and the danger of a
parasitic Transponder access is minimized.
Note:
•
The default value depends on the already released transponder driver.
3
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...