D-LGT:
(OperatingMode.ScanMode.DataSource.NoOfBytes)
D-LGT defines the length of raw data which are transmitted in the Scan-Mode.
Number of
data bytes
to be transferred, starting with the D-START.
Example:
data block
Byte
0
1
2
3
4
5
6
7
Data
0x01
0x23
0x45
0x67
0x89
0xAB
0xCD
0xEF
Output Data
0x23
0x45
0x67
0x89
D-START = 1
D-LGT = 4