![background image](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-prhd102/obid-i-scan-id-isc-prhd102_manual_3864973023.webp)
OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 23 of 125
H71101-2e-ID-B.doc
4.2. CFG1: Interface
The parameters of the CFG1 configuration block contains the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
TRANS-
FORM
1
0x00
0X00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x00
0x00
38400 Baud
e,8,1
5ms
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
RF-
INTERFACE
0x00
0x00
Interfaces
READER -
MODE
Default
0xF0
0x03
BT: 0x20
USB: 0x10
0x01
1,2 sec.
COM-ADR: (HostInterface.Serial.BusAddress)
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface,
especially for applications with the RS485 interface.
Notes:
•
Do not configure address 255!
•
Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at
any time. It answers then with the configured address.
•
Not available by the USB-Reader
1
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...