6.7.
[0x6E] Reader Diagnostic
The command Reader Diagnostic performs several hardware diagnostics on the Reader.
Host
→
Reader
1
2
3
4
5
6
7,8
0x02
8
COM-ADR
[0x6E]
MODE
CRC16
Host
←
Reader
1
2
3
4
5
6
7...n-2
n-1...n
0x02
n
COM-ADR
[0x6E]
STATUS
DATA
CRC16
MODE:
Reader Diagnostic Modes
0x04
Listing of detail information for STATUS = 0x10 (EEPROM-Failure)
0x20 Listing of detail information for STATUS = 0x18 (Wrong firmware)
DATA:
Response for Reader Diagnostic Modes
MODE = 0x04:
5-6
INT_ERROR
INT_ERROR:
Bit:
15
14
13
12
11
10
9
8
Function:
-
-
-
-
-
-
-
-
Bit:
7
6
5
4
3
2
1
0
Function:
-
-
-
-
RF-
Decoder
-
-
EE
DEV1
EE_DEV1:
Error during the communication with EEPROM Dev 1
RF-Decoder:
Error during the communication with RF-Decoder
MODE = 0x20:
ASCII-String with a description of the error.
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...