TR-DATA-3:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
-
COM
Prefix
COM Prefix: (OperatingMode.ScanMode.DataFormat.BusAddressPrefix)
( Scan Mode only) (not for USB reader)
b0:
no COM Prefix is send
b1:
The Reader will transmit the COM-ADR before each data set.
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
BANK_NR
BANK_NR: (OperatingMode.ScanMode.DataSource.BankNo)
In case of Class 1 Gen 2 Transponder BANK_NR is defined as follows:
b00
reserved
b01
EPC memory bank
b10
TID memory bank
b11
User memory bank
Note:
EPC Gen 2 memory banks can only be read in open state (Access Password).
DB-ADR
1
: (OperatingMode.ScanMode.DataSource.FirstDataBlock)
Address of first data block. Range: 0x0000...0xFFFF.
See for valid addresses:.
9.2. Supported ISO Host commands for ISO15693 Transponders
D-START: (OperatingMode.ScanMode.DataSource.FirstByte)
This parameter defines the first byte in the raw data (defined by DB-ADR and D-LGT),
which will be transferred in Scan-Mode. To transfer the whole data block D-START must be
set to 0.
Note:
The size of one data block depends on the type of Transponder.
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...