DB-N:
Number of data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface transmit buffer
size TX-BUF. The maximum number of DB-N is:
(TX-BUF - 10 )/(DB-Size+1) e.g. Block size 4 (DB-N = (512 – 10) / (4+1) = 100).
DB-SIZE:
Number of bytes of one data block. This value depends on the specification of the Trans-
ponder
SEC-STATUS:
(only ISO15693 Transponder)
Block security status of followed data block. If supported by the ISO15693 transponder.
DB:
Requested data block. The block size is defined by DB-SIZE.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS
= 0x95.
Notes:
•
Only one Transponder can be read in the non-addressed mode.
•
ISO15693:
- A read from 1 block uses a Read Single Block command to the ISO15693 Transponder.
- If a ISO15693 Transponder does not support Read Multiple Blocks commands several
Read Single Block commands are used for this Transponder.
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...