![background image](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-prhd102/obid-i-scan-id-isc-prhd102_manual_3864973031.webp)
OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 31 of 125
H71101-2e-ID-B.doc
4.5. CFG4: Transponder Parameters HF
The parameters of the CFG4 configuration block contain general HF-Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
ISO 15693
MODE
ISO 15693
AFI
ISO15693
OPTION
Default
0x0B
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
ISO-
Blocksize
Default
0x00
0x00
0x00
0x04
ISO 15693 MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
AFI
NO-TS
DATA-
RATE
SUB-
CARRIER
MOD
DATA
CODING
DATACODING (fix)
b1
Fast Mode (1 / 4)
MOD (fix)
b1
10% (the modulation depth in the setting
) are used
SUB-CARRIER (fix)
b0
ASK (one sub-carrier)
DATA-RATE (fix)
b1
high
NO-TS (fix) (Transponder.HF.ISO_15693.Anticollision.NoOfTimeslots)
b0
16 timeslots
AFI (Transponder.HF.ISO_15693.SelectionMask.Enable_AFI)
b0
Disabled
b1
Enabled
ISO 15693 AFI:
(Transponder.HF.ISO_15693.SelectionMask.AFI1)
Application Family Identifier to select a Transponder
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...