OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 123 of 125
H71101-2e-ID-B.doc
Label
Namespace
CFG-
Block
Start
Byte-
No.
No. of
Bytes
Start
Bit-No.
No. of
Bits
INTERFACE
HostInterface.Interfaces
1
12
1
0
4
READER-MODE:
OperatingMode.Mode
1
13
1
0
1
IDLE-STATE (GRN)
DigitalIO.Signaler.LED.Green.IdleState
2
3
1
0
2
IDLE-STATE (BLUE)
DigitalIO.Signaler.LED.Blue.IdleState
2
3
1
2
2
IDLE-STATE (BUZZER)
DigitalIO.Signaler.Buzzer.IdleState
2
3
1
4
2
Startup Buzzer / LED
DigitalIO.Signaler.Enable_StartupSignal
2
3
1
7
1
IDLE-FLASH (GRN)
DigitalIO.Signaler.LED.Green.IdleFlashFrequency
2
4
1
0
2
IDLE-FLASH (BLUE
DigitalIO.Signaler.LED.Blue.IdleFlashFrequency
2
4
1
2
2
IDLE-FLASH (BUZZER)
DigitalIO.Signaler.Buzzer.IdleFlashFrequency
2
4
1
4
2
ACTIVE-STATE (GRN)
DigitalIO.Signaler.LED.Green.ActiveState
2
7
1
0
2
ACTIVE-STATE (BLUE)
DigitalIO.Signaler.LED.Blue.ActiveState
2
7
1
2
2
ACTIVE-STATE
(BUZZER)
DigitalIO.Signaler.Buzzer.ActiveState
2
7
1
4
2
ACTIVE-FLASH (GRN)
DigitalIO.Signaler.LED.Green.ActiveFlashFrequency
2
8
1
0
2
ACTIVE-FLASH (BLUE
DigitalIO.Signaler.LED.Blue.ActiveFlashFrequency
2
8
1
2
2
ACTIVE-FLASH
(BUZZER)
DigitalIO.Signaler.Buzzer.ActiveFlashFrequency
2
8
1
4
2
ACTIV-GRN-TIME
DigitalIO.Signaler.LED.Green.ActivationTime
2
9
1
ACTIV-BLUE-TIME
DigitalIO.Signaler.LED.Blue.ActivationTime
2
10
1
ACTIV-BUZZER-TIME
DigitalIO.Signaler.Buzzer.ActivationTime
2
11
1
TAG-DRV
(Transponder.Driver.HF.Drivers)
3
1
1
TAG-DRV (D)
Transponder.Driver.HF.ISO_15693
3
1
1
3
1
ISO 15693 MODE (NO-
TS)
Transponder.HF.ISO_15693.Anticollision.NoOfTimeslots
4
4
1
4
1
ISO 15693 MODE (AFI)
Transponder.HF.ISO_15693.SelectionMask.Enable_AFI
4
4
1
5
1
ISO 15693 AFI
Transponder.HF.ISO_15693.SelectionMask.AFI1
4
5
1
ISO 15693 OPTION
Transponder.HF.ISO_15693.Miscellaneous.WriteOption
4
6
1
2
2
ISO-Read-Option
(Blocksize)
Transponder.HF.ISO_15693.Miscellaneous.
ReadOption.BlockSize
4
13
1
ISO-Read-Option
(Blocksize Selection)
Transponder.HF.ISO_15693.Miscellaneous.ReadOption.
BlockSizeSelection
4
13
1
5
1
ISO-Read-Option
(Read Mode)
Transponder.HF.ISO_15693.Miscellaneous.
ReadOption.ReadMode
4
13
1
6
2
TRIGGER-MODE
OperatingMode.ScanMode.Trigger.Mode
10
0
1
1
2
TR-DATA-1 (SNR)
OperatingMode.ScanMode.DataSelector.Uid
11
0
1
0
1
TR-DATA-1 (DB)
OperatingMode.ScanMode.DataSelector.Data
11
0
1
1
1
TR-DATA-1 (Byte Order)
OperatingMode.ScanMode.DataSource.ByteOrder
11
0
1
3
1
TR-DATA-3 (COM Prefix)
OperatingMode.ScanMode.DataFormat.
BusAddressPrefix
11
2
1
0
1
Bank
OperatingMode.ScanMode.DataSource.BankNo
11
3
1
0
2
DB-ADR
OperatingMode.ScanMode.DataSource.FirstDataBlock
11
4
2
D-START
OperatingMode.ScanMode.DataSource.FirstByte
11
11
1
D-LGT
OperatingMode.ScanMode.DataSource.NoOfBytes
11
12
2
VALID-TIME
OperatingMode.ScanMode.Filter.TransponderValidTime
12
0
2
DB-USE / DB-Format
OperatingMode.ScanMode.DataFormat.Format
13
0
1
0
4
SEP-CHAR
OperatingMode.ScanMode.DataFormat.SeparationChar
13
1
1
SEP-USR
Operating-
Mode.ScanMode.DataFormat.UserSeparationChar
13
2
1
END-CHAR
OperatingMode.ScanMode.DataFormat.EndChar
13
3
1
END-USR1
OperatingMode.ScanMode.DataFormat.UserEndChar1
13
4
1
Содержание OBID i-scan ID ISC PRHD102
Страница 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Страница 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Страница 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Страница 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...