DS4800 OM 

 
 

QUICK REFERENCE GUIDE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure A 

 
 

 

6

5

"POWER ON" LED

Indicator LEDs 

Laser Beam Output Window

 

Push Button

 

4

Display 

Focus Adjustment 

 

 
 

 

NOTE 

This manual illustrates a Stand Alone application. For other types of installations, such as 
ID-NET™, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using 
Genius™ configuration program, refer to the 

DS4800 

Reference Manual available on the CD. 

This manual is also downloadable from the Web at 

www.automation.datalogic.com/ds4800

4

2

1

3

5

6

Summary of Contents for DS4800 OM

Page 1: ...nual illustrates a Stand Alone application For other types of installations such as ID NET Pass Through Multiplexer Layout etc and for a complete scanner configuration using Genius configuration program refer to the DS4800 Reference Manual available on the CD This manual is also downloadable from the Web at www automation datalogic com ds4800 4 2 1 3 5 6 ...

Page 2: ... Log on to www automation datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software Utilities including Genius a utility program which allows device configuration using a PC It provides RS232 interface configuration SERVICES SUPPORT Datalogic Services Warrant...

Page 3: ...tage V Power Reference Outputs Earth Protection Earth Ground O1 Output 1 O1 Output 1 Inputs O2 Output 2 V Power Source External Trigger O2 Output 2 I1A External Trigger A polarity insensitive Auxiliary Interface I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference ...

Page 4: ...25 7 GND Power supply input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A polarity insensitive 10 I2B Input 2 B polarity insensitive 8 O1 Output 1 22 O1 Output 1 11 O2 Output 2 12 O2 Output 2 20 RX Auxiliary RS232 RX 21 TX Auxiliary RS232 TX 23 ID ID NET network 24 ID ID NET network ...

Page 5: ... into consideration these three ideal label position angles Skew 15 to 30 Tilt 0 and Pitch 0 The Skew angle refers to the most inclined or external raster line so that all other raster lines assure more than 15 Skew Assure at least 15 Minimize Minimize Figure 4 Skew Tilt and Pitch Angles 3 Refer to the Reading Diagrams in the Appendix of this Quick Reference Guide to decide the distance your scann...

Page 6: ... that all other laser lines assure more than 15 Skew This avoids the direct reflection of the laser light emitted by the reader 0 15 35 code surface 5 Figure 5 Oscillating Mirror Skew Angle Otherwise the scanner can be mounted at an angle of inclination of 15 in order to attain symmetrical deflection ranges 0 20 20 code surface 15 Figure 6 Oscillating Mirror Reading Position In the above case the ...

Page 7: ...the mechanical Focus Position 2 Using a screwdriver turn the focus adjustment screw in the desired direction clockwise focus nearer to the scanner or counterclockwise focus farther from the scanner The focus position in centimeters and inches is shown on the scanner display NOTE The value of the Focus Position must be stored in memory If the mechanical position changes by more than the allowed tol...

Page 8: ...orrectly powered NOTE When entering the X PRESS interface on the DS4800 Oscillating Mirror remains in the default fixed position 0 in order to make barcode reading easier while performing the X PRESS functions AUTO LEARN If you are configuring your scanner using X PRESS you must start with the Auto Learn procedure 1 Enter the Auto Learn function by holding the X PRESS push button pressed until the...

Page 9: ...ected the barcode This procedure ends either when the barcode is successfully decoded or after a timeout of about 7 seven seconds The scanner will restart at the end of the process and then the optimized reading parameters for that barcode are automatically configured in scanner memory FOCUS LOCK UNLOCK You must perform the Focus Lock procedure to save the mechanical focus position to memory If th...

Page 10: ...he factory default values you can perform this procedure by holding the X PRESS push button pressed while powering up the scanner At the end of the procedure about 5 6 seconds the Configuration and Environmental parameters are reset all LEDs blink simultaneously 3 times and the message Default Set is shown on the display ...

Page 11: ...re assumes scanner connection to a CBX100 500 Genius running on a laptop computer is connected to the scanner auxiliary port through the CBX100 500 9 pin connector To communicate with the scanner Genius performs an auto baudrate detection starting from its default parameters which are 115200 8 N 1 These parameters can also be set in the Genius Tools Options Communications window WIZARD FOR QUICK R...

Page 12: ...gger Presence Sensor using I1A and I1B inputs The Automatic operating mode does not require connection to an external Presence Sensor When working in this mode the reader is continuously scanning while the reading phase is activated each time a barcode enters the reader reading zone The reader stops reading after an N number of scans without a code Barcode characters are transmitted on the serial ...

Page 13: ...uration as follows Saving the configuration to disk Switching to Advanced mode Sending the configuration to the scanner 3 After sending the configuration to the scanner you have completed the configuration process 4 By clicking Finish the System Information window will be displayed with specific information concerning the scanner ...

Page 14: ... 5 to 35 Min Angle degrees This parameter is available only when working in Continuous oscillating mode It defines the minimum angle for the deflection range with respect to the angle perpendicular to the scanner 0 Selections a value from 5 to 35 Max Angle degrees This parameter is available only when working in Continuous oscillating mode It defines the maximum angle for the deflection range with...

Page 15: ... Oscillating Mode It defines the angle in degrees with respect to the angle perpendicular to the scanner 0 The default value is 10 Selections a value from 5 to 35 Second Zone Min Angle degrees This parameter is available only when the second reading zone is working in Continuous Second Zone Oscillating Mode It defines the minimum angle for the second zone deflection range with respect to the angle...

Page 16: ...on by holding the X PRESS push button pressed until the TEST LED is on 2 Release the button to enter the Test mode function Once entered the Bar Graph on the five LEDs is activated and if the scanner starts reading barcodes the Bar Graph shows the Good Read Rate In case of no read condition only the STATUS LED is on and blinks green green yellow yellow red READY GOOD TRIGGER COM STATUS SETUP LEARN...

Page 17: ...sing this option it is possible either to start a new scanner configuration or to open and modify an old one The desired parameters can be defined in the following window similar to the MS Explorer Figure 10 Genius Parameter Explorer Window ALTERNATIVE LAYOUTS The ID NET network is a built in high speed interface dedicated for high speed scanner interconnection ID NET is in addition to the Main an...

Page 18: ...Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Conditions Standard Reading Mode Linear Parameter selectable in Genius 0 0 corresponds to the scanner output window 0 5 15 10 30 in 20 25 35 40 0 10 20 30 40 50 60 70 80 90 100 cm 10 5 0 5 20 15 10 15 20 in 50 40 30 20 10 0 10 20 30 40 50 cm 0 50 mm 20 mils 0 30 mm 12 mils 0 20 mm 8 mils 0 38 mm 15 mils ...

Page 19: ...0 cm 10 5 0 5 20 15 10 15 20 in 50 40 30 20 10 0 10 20 30 40 50 cm 0 38 mm 15 mils 0 50 mm 20 mils 0 30 mm 12 mils DS4800 OM X1XX Focus Distance 60 cm Far CONDITIONS Code Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 to 30 Scan Speed 800 scans sec Reading Conditions Standard Reading Mode Linear Parameter selectable in Genius 0 0 corresponds to the scanner output window 0 5 15 10 30 in...

Page 20: ...onductor laser diode Wavelength In the range 630 to 680 nm Safety Class Class 2 EN 60825 1 CDRH READING FEATURES Scan Rate software programmable 600 to 900 scans sec Aperture Angle 50 Oscillating Amplitude 40 5 to 35 Oscillating Frequency 0 2 to 20 Hz 5 Hz max 40 20 Hz max 10 Maximum Reading Distance Maximum Resolution See reading diagrams ENVIRONMENTAL FEATURES Operating Temperature 0 to 50 C 32 ...

Page 21: ... 39 13 0 51 42 1 65 42 5 1 67 48 4 1 90 MØ5 MØ5 5 9 0 23 41 5 1 63 10 0 39 MØ5 116 6 4 59 101 3 98 Figure 11 DS4800 OM Overall Dimensions 8 1 0 3 2 N 2 3 0 12 108 4 25 30 1 18 64 2 2 53 70 2 76 Ø5 5 Ø0 22 N 2 56 2 20 15 15 45 45 9 0 35 27 5 1 08 45 45 4 5 4 5 15 15 15 1 5 64 2 2 53 Ø5 5 Ø0 22 71 6 2 82 100 6 3 96 103 4 06 74 2 91 76 9 3 03 Figure 12 Mounting Bracket Overall Dimensions mm in mm in ...

Page 22: ...www datalogic com Figure 13 Warning and Device Class Labels FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept a...

Page 23: ...UICK GUIDE 23 PATENTS This product is covered by one or more of the following patents U S patents 5 992 740 6 394 352 B1 6 742 710 B2 6 688 524 B1 European patents 789 315 B1 959 426 B9 Additional patents pending ...

Page 24: ...ember States relating to electromagnetic compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a...