3-16
Basic key operation
Before checking the running status on the drive monitor, set function code E52 to "2" (Full-menu
mode).
(1) When the inverter is powered on, it automatically enters Running mode. In that mode, press the
key to switch to Programming mode. The function selection menu appears.
(2) With the menu displayed, use the
and
keys to select "Drive monitoring" (
#ope
).
(3) Press
the key to display the desired code in the monitoring item list (e.g.
3_00
).
(4) Use
the and
keys to select the desired monitoring item, then press the
key.
The running status information for the selected item appears.
(5) Press the key to return to the monitoring item list. Press the
key again to return to the
menu.
Table 3.8 Drive Monitoring Display Items
LED
monitor
shows:
Contents Unit
Description
3_00
Output frequency
Hz
Output frequency before slip compensation
3_01
Output frequency
Hz
Output frequency after slip compensation
3_02
Output current
A
Present output current
3_03
Output voltage
V
Present output voltage
3_05
Reference
frequency
Hz
Present reference frequency
3_06
Running direction
N/A
Displays the running direction being outputted.
F: forward; R: reverse, – – – –: stop
3_07
Running status
N/A
Displays the running status in hex. format. Refer to "
Displaying
running status
" on the next page.
3_09
Load shaft speed
(line speed)
r/min
(m/min)
The unit for load shaft speed is r/min and that for line speed is
m/min.
Display value = (Output frequency Hz before slip compensation)
×
(Function code E50)
appears for 10,000 (r/min or m/min) or more. When
is displayed, the data is overflowing, which means that the func-
tion code should be reviewed. For example:
Load shaft speed = Displayed data
×
10 (r/min)
3_10
PID process
command
N/A
The command is displayed through the use of function code E40
and E41 data (PID display coefficients A and B).
Display value = (PID process command)
×
(Coefficient A - B) + B
If PID control is disabled, "– – – –" appears.
3_11
PID feedback
value
N/A
This value is displayed through the use of function code E40 and
E41 data (PID display coefficients A and B).
Display value = (PID feedback value)
×
(Coefficient A - B) + B
If PID control is disabled, "– – – –" appears.