54
S
ervice Handbook | English
D
STOP TEST
To end the test, actuate the
Stop test
button.
E
CALIBRATION
The torque sensor can be automatically calibrated with this button.
This action is fully automatic and stops of its own accord after a few
seconds. Please also see Chapter
ATTENTION! As part of the calibration, the system is
activated for three seconds, during which the rear wheel,
chain, and pedals will move! Please observe the general
safety instructions!
3.8.1 Calibration
This function is required when:
The bottom bracket has been reinstalled,
New cranks have been installed,
The spider has been installed/uninstalled.
ATTENTION! The motor also moves the pedals, chain, and rear wheel. Ensure that the rear wheel
can move freely and the USB cable is not tangled and cannot get caught on the pedals.
You have to end the test drive mode before carrying out calibration. To do so, press the Stop
test button
D
, wait until the motor has stopped, and then carry out calibration.
A pop-up window informs you of the motor being activated:
ATTENTION! Error-free operation of our Drive Systems cannot be guaranteed without successful
calibration!
The calibration in complete after around three seconds and the rear wheel can be stopped using
the rear brake.