- 14
IF THE MACHINE WILL BE SUBJECT TO MISUSE OR VANDALISM, IT IS
RECOMMENDED THAT THE VENDOR BE SECURED TO THE FLOOR OR
WALL TO MINIMIZE RISK OF INJURY OR DEATH FROM TIPPING.
CALL THE FASTCORP TECHNICAL SERVICE DEPARTMENT AT
(888) 441-3278 FOR ASSISTANCE.
Adjust the front leveling legs, to level the cabinet front-to-rear then adjust the
front and rear legs an equal number of turns to level left to right.
A maximum of
1-inch of thread is visible when the leveling leg is fully extended. Do not
extend the leg beyond this point.
A carpenter’s level placed on top of the
machine (front to back & left to right) will help verify that the machine is level.
Leveling legs are adjusted using an adjustable wrench, pliers or a 1-3/8-inch
open end wrench. Lowering the legs will raise the machine approximately 1/4”
per 4 turns. If the machine is to be used next to another vendor, compare the top
and side for proper alignment. Minimum leg extensions should be used in
leveling and alignment to attain greater stability. Make sure that all the leveling
legs are in contact with the floor and that the machine does not rock. If you
cannot level the vendor, select another location. Do not place any objects under
the machine. Leveling is extremely important to ensure proper vendor operation.
Do not program or operate the machine before the leveling process is complete.
If preprogramming selections in a warehouse prior to placement, the machine
must be leveled again at the new location and all the program selections checked
for proper robot to bin alignment.
POSITIONING THE MACHINE
Maintain a distance of at least 4 inches / 10 cm between the rear wall of the
vendor and any obstructions to ensure adequate ventilation airflow. Pay special
attention to the air vents at the top and the fan louvers at the bottom of the rear
cabinet wall.
Opening the Front Door:
The T-Handle keys can be found in the Coin Change Pocket. The T-Handle lock
cylinder and keys that come with each Evolution Vendor are common to all
machines shipped from Fastcorp, LLC. All shipping locks should be replaced
before the machine is placed on location.
Power Supply Cord FS-01:
The FS01 Evolution Vendor power supply cord is equipped with a resettable
Ground Fault Circuit Interrupt device (GFCI). Care should be taken when
handling the GFCI module. Damage may occur if dropped onto a hard surface.
The end of the power supply cord with the GFCI device is placed into the
Delivery Bin to protect it during transport.