Figure 3-41 External Control Signal Wiring
The FT68200 series load provides an external control signal port on its rear panel. This
port receives TTL level signal, low level is effective, and its filtering time is about 20ms.
There are 3 ways to use the external control signal:
Trigger: Used as a trigger signal by default. The input port detects a valid
low-level pulse, that is, a trigger signal is received. In dynamic PULS mode and
dynamic TOGG mode, the trigger signal can switch the load current; in the
automatic test function, the trigger signal can switch the running step to the next
step;
Toggle: As the input switch control signal. The input port detects a valid low-level
pulse, that is, the input switch is switched once, which has the same effect as the
button;
Hold: as the input switch control signal. When the input port detects a valid low
level, the load input is turned on, and when a valid high level is detected, the load
input is turned off.
Operation Procedures
1. Press
(Menu) to go to main menu;
2. Select “Set” -> “APG” and press
;
3. Select “Ext-S” to set, can be set as Trigger, Toggle, or Hold;
4. Press
to validate the input.
Содержание FT68200 Series
Страница 9: ...Faithtech FT68200 Operation Manual 3 1 3 2 7U 8kW 10kW 12kW...
Страница 10: ...Faithtech FT68200 Operation Manual 4 1 3 3 11U 14kW 16kW 18kW...
Страница 11: ...Faithtech FT68200 Operation Manual 5 1 3 4 14U 20kW 22kW 24kW...
Страница 12: ...Faithtech FT68200 Operation Manual 6 1 3 5 20U 30kW 36kW...
Страница 13: ...Faithtech FT68200 Operation Manual 7 1 3 6 26U 42kW 48kW...
Страница 14: ...Faithtech FT68200 Operation Manual 8 1 3 7 32U 54kW 60kW...