Faithtech FT68200 Operation Manual
52
3. Set “Run file”, press
to confirm the input;
4. Press
to start sequence test.
"Step: XX" displays the sequence step number which is running, and "Cycle: XXXXX"
displays the number of completed cycles of the sequence file.
Sequence test can realize complex waveforms, such as the waveform described in the
figure below.
Figure 3-19 Sequence Waveform
3.18. Discharge Test
The discharge test function is used to measure battery power and can also be used to
discharge super capacitors. The discharge test supports 3 discharge modes: CC, CR and CP.
During the discharge process, the load measures its discharge power (unit AH), discharge
energy (unit WH) and discharge time (XX:XX:XX). When the battery voltage is lower than
the "End Volt", or the discharge power reaches the set value, or reaches the set discharge
time, the load will automatically stop discharging the battery. The allowable setting range
of discharge time is 0
~
360000s, and the allowable setting range of discharge power is
0.0
~
999999AH.
Operation Procedures
1. Press
(Test) to go to “Test” function selection;
2. Rotate the knob to select “DISC”, press
, the screen displays as follows:
Содержание FT68200 Series
Страница 9: ...Faithtech FT68200 Operation Manual 3 1 3 2 7U 8kW 10kW 12kW...
Страница 10: ...Faithtech FT68200 Operation Manual 4 1 3 3 11U 14kW 16kW 18kW...
Страница 11: ...Faithtech FT68200 Operation Manual 5 1 3 4 14U 20kW 22kW 24kW...
Страница 12: ...Faithtech FT68200 Operation Manual 6 1 3 5 20U 30kW 36kW...
Страница 13: ...Faithtech FT68200 Operation Manual 7 1 3 6 26U 42kW 48kW...
Страница 14: ...Faithtech FT68200 Operation Manual 8 1 3 7 32U 54kW 60kW...