Faithtech FT68200 Operation Manual
70
designated location for the user to recall and use conveniently. If shortcut recall feature is
enabled, just press a number key to recall the saved parameters. This function can
significantly reduce user operations and improve test efficiency.
Operation Procedures
When the user needs to use the save and recall function, the test function parameters
should be configured first. Take the CC and CV functions as an example to illustrate:
1. Switch to CC mode and set the current to 10A;
2. Press
(Save) to enter into save interface;
3. Input number 1, press
to confirm, thus save CC.10A to position 1;
4. Switch to CV mode and set the voltage to 30V;
5. Press
(Save) to enter into save interface;
6. Input number 2, press
to confirm, thus save CV.30V to position 2;
7. Press
(Recall) to enter into recall interface;
8. Input number 1, press
to confirm, the parameter stored in position 1 will
be called, and the load will switch to constant current mode, and its load current
is 10A;
9. Press
(Recall) to enter into recall interface;
10. Input number 2, press
to confirm, the parameter stored in position 2 will
be called, and the load will switch to constant voltage mode, and its load voltage
is 30V.
Shortcut Recall
1. Press
(Menu) to go to main menu;
2. Select “System”->“Others”, press
;
3. Set “Shortcut” to “ON”, so as to enable shortcut recall function;
Содержание FT68200 Series
Страница 9: ...Faithtech FT68200 Operation Manual 3 1 3 2 7U 8kW 10kW 12kW...
Страница 10: ...Faithtech FT68200 Operation Manual 4 1 3 3 11U 14kW 16kW 18kW...
Страница 11: ...Faithtech FT68200 Operation Manual 5 1 3 4 14U 20kW 22kW 24kW...
Страница 12: ...Faithtech FT68200 Operation Manual 6 1 3 5 20U 30kW 36kW...
Страница 13: ...Faithtech FT68200 Operation Manual 7 1 3 6 26U 42kW 48kW...
Страница 14: ...Faithtech FT68200 Operation Manual 8 1 3 7 32U 54kW 60kW...