Faithtech FT68200 Operation Manual
37
In continuous mode, the electronic load will continuously switch between CC-1 and CC-2.
Unless you exit the dynamic test or turn off the load, the load will continue to execute
according to the set parameters, and this method is not affected by the trigger signal.
Figure 3-10 CONT Mode
1. Set “Way” as CONT;
2. Set “CC-1” and “CC-2”;
3. Set “Width-1” and “Width-2”, setting range 0.01
~
60000ms;
4. Set “Slew-UP” and “Slew-DN”, unit A/us;
5. Press
to start test.
PULS Mode (Pulse)
In PULS mode, if a trigger signal is received, the load will immediately switch from
CC-1 to CC-2, and then return to CC-1 after maintaining pulse width -2.
Figure 3-11 PULS mode
1. Set “Way” as PULS;
2. Set “CC-1” and “CC-2”;
3. Set “Slew-UP” and “Slew-DN”, unit A/us;
4. Set “Width-2”, setting range 0.01
~
60000ms;